Chapter 29 Diagnostic

Loopback test - checks if the MEP port receives its Loop Back Response (LBR) from its target after it sends the Loop Back Message (LBM). If no response is received, there might be a connectivity fault between them.

Link trace test - provides additional connectivity fault analysis to get more information on where the fault is. If an MEP port does not respond to the source MEP, this may indicate a fault. Administrators can take further action to check and resume services from the fault according to the line connectivity status report.

29.3The General Diagnostic Screen

Click Maintenance > Diagnostic to open the screen shown next. Ping and traceroute help check availability of remote hosts and also help troubleshoot network or Internet connections.

Figure 198 Maintenance > Diagnostic > General

The following table describes the fields in this screen.

Table 135 Maintenance > Diagnostic > General

LABEL

DESCRIPTION

TCP/IP

Type the IP address of a computer that you want to ping in order to test a

Address

connection or trace the route packets take to.

 

 

Ping

Click this button to ping the IP address that you entered.

 

 

Traceoute

Click this button to perform the traceroute function. This determines the

 

path a packet takes to the specified host.

 

 

380

 

P-2812HNU-51c User’s Guide