204 7 Programming: Canned Cycles, sub-programs
7.3 Probing Cycles
To use the automatic tool preset:
Field Code Description
OvrSlwFeed S This is the override for the slow feedrate
that was set in the machine setup
parameter ZFirstPickFeedRate_Slow.
This is used for the same reason as the F
cycle parameter. This can only be set
slower. Trying to set this higher will
result in the software using the original
feedrate. (Optional)
OvrRPM R This is the override for the RPM that was
set in the machine setup parameter
calibAndToolMeasurementRPM. This is
used for the same reason as the F cycle
parameter. This can only be set slower.
Trying to set this higher will result in the
software using the original RPM.
(Optional)