ACU-RITE 3500i 33
2.1 Fundamentals of Positioning
Example2: SetZero
See "Absolute Zero Set" on page 138 for more information on using the
SetZero cycle. The work piece drawing shows holes (1 to 4) whose
dimensions are shown with respect to an absolute datum with the
coordinates X=0 Y=0. Holes 5 to 7 are dimensioned with respect to a
relative datum with the absolute coordinates X=450, Y=750. With the
SetZero cycle you can temporarily set the datum to the position
X=450, Y=750, to be able to program holes 5 to 7 without further
calculations.
Format: SetZero X450 Y750