Field

Code

Description

DistDown

E

The incremental distance from the current Z

 

 

Retract amount to go down along the side

 

 

of the probe stylus when doing a diameter

 

 

pick. The maximum E value is 0.55" (13.97

 

 

mm) or the tool may crash into the probe or

 

 

table. If you enter a value larger than 0.55"

 

 

(13.97 mm), the control issues an error

 

 

message. If E is not set, the cycle uses a

 

 

default value of 0.1" (2.54 mm). (Optional)

 

 

[Default: 0.1"]

 

 

Ball nose cutters and special cutters that

 

 

require a move down more than 0.55"

 

 

(13.97 mm) are not supported.

 

 

Z Retract Amount is set in the Tool Probe

 

 

Parameters.

 

 

 

Update

U

If this is undefined or set to 0, the G154

 

 

cycle does not update the diameter or

 

 

length wear register each time it checks a

 

 

tool. If set to one, the cycle updates the

 

 

wear registers. In both cases, the control

 

 

alarms when the maximum limit set in K or

 

 

J has been exceeded. (Optional)

 

 

 

ToolLife

Q

Select Yes or No if the Tool Life has been

 

 

entered into the Tool Table for the tool in

 

 

use.

 

 

 

OvrMed

M

This is the override for the medium feedrate

Feed

 

that was set in the machine setup

 

 

parameter ZFirstPickFeedRate_Medium.

 

 

Sometimes there may be a tool that has a

 

 

large diameter making it necessary to slow

 

 

it down to prevent the touch probe from

 

 

being hit too hard. This can only be set

 

 

slower. Trying to set this higher will result in

 

 

the software using the original feedrate.

 

 

(Optional)

 

 

 

7.3 Probing Cycles

ACU-RITE 3500i

215

Page 241
Image 241
Acu-Rite CNC 3500i user manual 215