Field

Code

Description

OvrSlw

S

This is the override for the slow feedrate

Feed

 

that was set in the machine setup

 

 

parameter ZFirstPickFeedRate_Slow. This

 

 

is used for the same reason as the M cycle

 

 

parameter. This can only be set slower.

 

 

Trying to set this higher will result in the

 

 

software using the original feedrate.

 

 

(Optional)

 

 

 

OvrRPM

R

This is the override for the RPM that was

 

 

set in the machine setup parameter

 

 

calibAndToolMeasurementRPM. This is

 

 

used for the same reason as the M cycle

 

 

parameter. This can only be set slower.

 

 

Trying to set this higher will result in the

 

 

software using the original RPM. If you

 

 

would like the cycle to run without the

 

 

spindle turning, enter a negative value in

 

 

the "R" parameter. (Optional)

 

 

 

7.3 Probing Cycles