User Macros (G65, G66, G67)

Use G66 when you want to use a modal macro sub-program. These groups of instructions can be special canned cycles made up by the user to simplify the programming of the particular part, or master programs for similar part families, programmed with variables rather than fixed dimensions.

Macros can contain automatic measuring sequences for sensors, such as a probe, for feedback to the 3500i.

Format #

Function

G65

Pn Ln

Non-modal macro call. Call macro n. Execute

 

 

macro, at the current position, only once. The

 

 

sub-program can be looped (L).

 

 

 

G66

Pn

Modal macro call. Call macro n. Execute macro

 

 

at any X and/or Y location given after the G66

 

 

code, until G67 (cancel) is called. G66 stays

 

 

active until G67 is called.

 

 

 

G67

 

Cancel Modal Macro Call (G66).

 

 

 

11.4 Advanced Programming

ACU-RITE 3500i

407

Page 433
Image 433