Chapter 10. Statistics

To configure the interval time frame, go to the SYSTEM

CONFIGURATION menu under HISTORY INTERVAL SIZE and select the

time you want the history interval to be set for (from 5 to 30 minutes, in five minute intervals). The TSU IQ+ gathers and displays the information according to the time selected. An example of a STATISTICS screen in the VIEW BY INTERVAL format is shown in Figure 10-2 on page 10-5.

The TSU IQ+ cuts the first gathering session short in order to begin fall- ing on the selected time boundary. For example: If the unit or the statistics information was last reset at 12:03 and the History Interval is set for five minutes, then the first interval session will last only two minutes. There- fore, the first interval column (i.e., the column farthest to the right if no columns have been deleted yet) normally represents a time shorter than the other columns.

View by Day

This view provides historical information for the last seven days (not including the current day). The most recent information is displayed on the left. An example of a STATISTICS screen in the VIEW BY DAY format is shown in Figure 10-3 on page 10-5.

The first day's column (i.e., the column furthest to the right) does not rep- resent a full day's worth of information (unless the unit or the statistics information was reset at exactly 12 AM).

61200275L1-1

TSU IQ+ User Manual

10-3

Page 115
Image 115
ADTRAN 1204002L2, TSU IQ+ user manual View by Day