Chapter 4. Applications
Minimum Configuration Requirements
The following options (all found in the SYSTEM portion of the CONFIGURATION menu) are the minimum configuration requirements for establishing
IP Address
Enter the TSU IQ+ IP address.
Control Port Options
If necessary, select SLIP or PPP as the TSU IQ+ CONTROL PORT OPTIONS. If the ethernet card is the interface type, this parameter does not affect setup. This selection is found in the SYSTEM portion
of the CONFIGURATION menu.
Subnet Mask
Enter the subnet mask number assigned to the network formed by the TSU IQ+ and the other FRAD/routers across the frame relay network. This address is available from the network administrator and is only necessary when using the ethernet card.
Gateway IP Address (if required)
Enter the Gateway node IP address. This address is applicable only if the TSU IQ+ and the network manager are connected through a Gateway node. This address is available from the network administrator and is only necessary when using the ethernet card.
The next five settings are applicable for SNMP access only.
Read Community
Set the READ COMMUNITY name to match the NMS (network management system) settings.
Write Community
Set the WRITE COMMUNITY name to match the NMS settings.
Trap Manager DLCI
Identify the virtual circuit used for all traps generated by the TSU IQ+. This selection is found in the SYSTEM portion of the
CONFIGURATION menu.
TSU IQ+ User Manual |
|