Chapter 10. Statistics
Signal Error
Number of signal frames received with PVC signaling protocol violations.
Signal Timeouts
Number of T392 timeouts that have occurred.
Signal State Change
Number of changes in the signaling protocol state.
Rx Full Status
Number of full status polls received on the DTE side.
Rx LI Only
Number of link integrity (LI) only polls received on the DTE side.
On the DTE side, transmit and receive counts for full status and link in- tegrity polls would be identical. Therefore, only receive counts are given.
Discard Frame
Number of frames discarded by the TSU IQ+ due to bad IP frames received on the management DLCI, transmission errors, or link violations. This count includes ABORTS, CRC ERRORS, OCTET
ALIGN, and LENGTH ERRORS.
Aborts
Number of frames received without a closing flag. This transmission error is also reflected in the DISCARD FRAME field.
CRC Errors
Number of frames received with CRC violations. This transmission error is also reflected in the DISCARD FRAME field.
Octet Align
Number of frames received with a bit count that does not fall on
DISCARD FRAME field.