Chapter 6. Data Port Configuration

Follow RTS

The CTS lead is on when the RTS lead is on (and off when the RTS lead is off).

DSR Option

Set the DSR lead to FORCED ON or NORMAL.

Forced On

The DSR lead is always on.

Normal

The DSR lead is off when the TSU IQ+ is in a loopback test or an alarm state.

CD Option

Set the CD lead to FORCED ON or NORMAL.

Forced On

The CD lead is always on.

Normal

The CD lead is off when the TSU IQ+ is in alarm state.

TC Clock Option (TC CLOCK OPT)

Normal

Clock for DTE's transmit data normal phase.

Inverted

Clock for DTE's transmit data inverted phase. May be used in high speed circuits (>512 kbps) when the DTE's V.35 interface has high delay. This is usually indicated by HDLC errors on the TSU IQ+'s DTE port.

External

Clock for the DTE’s transmit data is derived from the external DTE device connected to the TSU IQ+.