Chapter 6: Connecting Accessories

38-pin Low-voltage Probe (E5339A with tip isolation network)

 

38-pinLow-voltage Probe (E5339A with tip isolation network)

 

 

NOTE:

For all Agilent logic analyzers except 16517A, 16518A, 16760A, and

 

16753/54/55/56A.

 

The 38-pin low-voltage probe provides a convenient way to connect

 

 

two Agilent Technologies logic analyzer probe cables to a small area of

 

a target system. The Agilent E5339A probe has isolation networks in

 

the cable end that connects to the high-density AMP MICTOR

 

(Matched Impedance ConnecTOR) connector. It is designed to be

 

compatible with low-amplitude digital signals, down to 250 mV p-p.

Logic Analyzer

Pod

AMP "MICTOR 38"

Connector Pinout

Probe Cable

(with RC network)

+5VDC

1

GND DC

3

 

CLK

5

 

D15

7

 

D14

9

Pod

D13

11

D12

13

D10

17

 

D11

15

Even

D9

19

D8

21

 

D7

23

 

D6

25

 

D5

27

 

D4

29

 

D3

31

 

D2

33

 

D1

35

 

D0

37

2

Do not connect

4

Do not connect

6

CLK

 

8

D15

 

10

D14

 

12

D13

 

14

D12

Pod

18

D10

16

D11

 

20

D9

Odd

22

D8

24

D7

 

26

D6

 

28

D5

 

30

D4

 

32

D3

 

34

D2

 

36

D1

 

38

D0

 

Note: +5V is supplied from the logic analyzer to provide power for analysis probes and demo boards. DO NOT connect these pins to a +5V supply in the target system!

Shroud

Amp "MICTOR 38”

Equivalent Load

220 ohm

Signal

50.5k

Connector

3pF 18pF

Ground

ohm

Includes logic analyzer and MICTOR connector.