Chapter 6: Connecting Accessories
38-pin  Low-voltage  Probe (E5339A with tip isolation network)
| 
 | |
| 
 | 
 | 
| NOTE: | For all Agilent logic analyzers except 16517A, 16518A, 16760A, and | 
| 
 | 16753/54/55/56A. | 
| 
 | The  | 
| 
 | |
| 
 | two Agilent Technologies logic analyzer probe cables to a small area of | 
| 
 | a target system. The Agilent E5339A probe has isolation networks in | 
| 
 | the cable end that connects to the  | 
| 
 | (Matched Impedance ConnecTOR) connector. It is designed to be | 
| 
 | compatible with  | 
Logic Analyzer
Pod
AMP "MICTOR 38"
Connector Pinout
Probe Cable
(with RC network)
| +5VDC | 1 | |
| GND DC | 3 | |
| 
 | CLK | 5 | 
| 
 | D15 | 7 | 
| 
 | D14 | 9 | 
| Pod | D13 | 11 | 
| D12 | 13 | |
| D10 | 17 | |
| 
 | D11 | 15 | 
| Even | D9 | 19 | 
| D8 | 21 | |
| 
 | D7 | 23 | 
| 
 | D6 | 25 | 
| 
 | D5 | 27 | 
| 
 | D4 | 29 | 
| 
 | D3 | 31 | 
| 
 | D2 | 33 | 
| 
 | D1 | 35 | 
| 
 | D0 | 37 | 
| 2 | Do not connect | |
| 4 | Do not connect | |
| 6 | CLK | 
 | 
| 8 | D15 | 
 | 
| 10 | D14 | 
 | 
| 12 | D13 | 
 | 
| 14 | D12 | Pod | 
| 18 | D10 | |
| 16 | D11 | 
 | 
| 20 | D9 | Odd | 
| 22 | D8 | |
| 24 | D7 | 
 | 
| 26 | D6 | 
 | 
| 28 | D5 | 
 | 
| 30 | D4 | 
 | 
| 32 | D3 | 
 | 
| 34 | D2 | 
 | 
| 36 | D1 | 
 | 
| 38 | D0 | 
 | 
Note: +5V is supplied from the logic analyzer to provide power for analysis probes and demo boards. DO NOT connect these pins to a +5V supply in the target system!
Shroud
Amp "MICTOR 38”
Equivalent Load
220 ohm
Signal
 50.5k
 50.5k
Connector
3pF 18pF
Ground
ohm
Includes logic analyzer and MICTOR connector.