ROOF 30" (76.2 CM)

WARNING

Solvent gases and vapors from dry cleaning machines create acids when drawn through the heater of a drying tumbler. These acids are corrosive to the drying tumbler as well as to the laundry load being dried. Be sure make-up air is free of solvent gases and vapors.

If the dry cleaning machines are in the same area as the tumbler, then the tumbler make-up air must come from a source free of solvent gases and vapors.

W058

WARNING

To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building.

W059

FOR BEST PERFORMANCE provide an individual exhaust duct for each drying tumbler. Do not install a hot water heater in room containing drying tumblers. It is better to

have the water heater in a separate room with a separate air inlet.

NOTE: Do not install wire mesh or screen in this opening as lint will build up and prevent proper discharge of air from drying tumblers.

T075IE3A

ROOF 30" (76.2 cm)

 

 

 

 

CEILING

 

 

 

WALL

REMOVABLE STRIP OF PANEL IN FRAMING WALL

 

 

TO PERMIT REMOVAL OF DRYING TUMBLER

 

36 INCHES

FROM FRAMING WALL

PARTITION OR

(91.4 cm)

 

RECOMMENDED

 

BULKHEAD

 

SERVICE AREA

 

 

 

 

24 INCHES

 

 

(61.0 cm)

 

 

MINIMUM

ONE

DRYING

TUMBLER

TWO

T108IE3ADRYING

TUMBLERS

T108IE3C

CONSULT YOUR LOCAL BUILDING CODE FOR REGULATIONS WHICH MAY ALSO APPLY

 

THREE

NOTE: Inside of duct shall be

 

 

DRYING

smooth. Do not use sheet

 

 

TUMBLERS

metal screws to join sections.

 

 

 

 

 

 

Figure 3

 

 

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414545