FINAL OPERATING CHECKS

OPL MICRO CONTROL TUMBLER

Refer to OPL micro-control section to check control for proper operation.

MANUAL DUAL TIMER TUMBLER Refer to Figure 13.

1.Set the TEMPERATURE selector to the desired temperature, and set the DRYING and COOLING selectors to maximum.

2.Press the PUSH-TO-START button in and hold it in for approximately three seconds. The motor will start, the heat system will come on and the DRYING indicator will light.

3.During the drying period the DRYING selector rotates counterclockwise. When the DRYING selector reaches “0” the heat system will shut off, the DRYING indicator will go out and the COOLING indicator will light.

During the cooling period the COOLING selector rotates to the left. When the COOLING selector reaches “0” the motor will stop and the COOLING indicator will go out indicating the end of the cycle.

COIN-OPERATED TUMBLER Refer to Figure 14.

1.Set the TEMPERATURE selector to the desired temperature.

2.Insert required number of coins in the coin slot and turn the knob fully clockwise and release it. The RUN indicator (option) will light.

For Coin Slide Models — Place required number of coins in coin slide and push slide in as far as possible, then release.

3.Press the PUSH-TO-START button in and hold it in for approximately three seconds. The motor will start and the heat circuit will come on.

4.An automatic preset 2-1/2 minute cool-down period occurs near the end of the cycle. During this period the heat system is off and encompassing air circulates through the load to cool it.

5.When the coin metered time expires, the cycle is completed.

38

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414545