MONTHLY

BELT TENSION
LUBRICATION

Check belt tension and adjust if needed. Refer to

appropriate section.

WARNING

To reduce the risk of serious injury or death, disconnect the power to the tumbler before performing this operation.

W080

Motor bearings, idler housing bearings and trunnion bearings are pre-lubed sealed bearings and require no lubrication.

LINT REMOVAL

1.Remove the exhaust duct from the exhaust thimble and remove lint. If excessive lint is evident at the thimble, further disassemble the duct work and remove lint.

2.On Energy Saver Gas Models:

Remove the cleanout cover at the bottom of the vertical duct and clean out lint.

EVERY THREE MONTHS

LINT REMOVAL

WARNING

To reduce the risk of serious injury or death, disconnect power to the tumbler before performing these operations.

W081

1.Clean the lint and any other foreign materials from the air vents located on the front and back of the drive motor. The drive motor is air cooled and if the air vents become clogged, the motor will overheat and the internal thermal overload protector will cycle off.

2.Steam Models: Check the steam coils and remove any lint buildup and/or replace air filter in the coil fin area. This can be accomplished by using compressed air or by fabricating a comb that can be pulled across the fin area of the coil.

3.Exhaust ducts should be periodically inspected to ensure there has been no buildup of lint which could obstruct the airflow.

4.Inspect the dryer area to make sure nothing is obstructing the flow of combustion and ventilation air.

5.Remove front panel and clean any lint buildup.

EVERY SIX MONTHS

OVERALL CHECK

WARNING

To reduce the risk of serious injury or death, disconnect the power to the tumbler before performing this operation.

W080

Check the tumbler over thoroughly for loose nuts, bolts and screws, and for loose gas, steam and/or electrical connections.

GAS CONNECTIONS: (Unions, flared tube fittings) Check for leakage that might be caused by vibration. Use a mild soap solution. DO NOT USE A FLAME AT

ANY TIME TO CHECK FOR GAS LEAKS.

ELECTRICAL CONNECTIONS: Electrical service and grounding connections should be examined for proper tightness.

66