GAS REQUIREMENTS

WARNING

To reduce the risk of fire or explosion, DO NOT CONNECT THE GAS LINE TO THE TUMBLER IF THE GAS SERVICE IS NOT THE SAME AS THAT SPECIFIED ON THE TUMBLER SERIAL PLATE! It will first be necessary to convert the gas burner orifice and gas valve. Appropriate conversion kits are available.

W060

IMPORTANT: Any product revisions or conversions must be made by the Manufacturer’s Authorized Dealers, Distributors or local service personnel.

WARNING

The tumbler and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).

The tumbler must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig (3.45 kPa).

W061

IMPORTANT: The installation must comply with local codes or, in the absence of local codes:

with the latest edition of the “National Fuel Gas Code”, ANSI Z223.1 in the U.S.A.

with CAN1-B149.1 or CAN1-B149.2 in Canada

and Australian Gas Association/Australian L.P. Gas Association requirements in Australia

The size of gas service pipe is dependent upon many variables (lengths, tees, etc.). Specific pipe size information should be obtained from the gas supplier. Refer to Table 2 for general pipe size.

A dirt and water vapor pipe trap must be furnished and installed by customer. Refer to Figure 6.

It is important that equal pressure be maintained at all tumbler gas connections. This can best be done by installing a one inch (2.54 cm) pipe gas loop. Refer to Figure 7.

WARNING

To reduce the risk of fire or explosion, if the tumbler is to be connected to Liquefied Petroleum (L.P.) gas, a vent to the outdoors must be provided in the room where the tumbler is installed.

W062

NATURAL GAS service must be supplied at 6-1/2 ± 1-1/2 inch water column pressure (1.62 ± .37 kPa).

L.P. GAS service must be supplied at 11 ± .3 inch water column pressure (2.74 ± .07 kPa).

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414545