SECURITY LOCK-OUT

The programming pads can be “locked out” so operators cannot change cycles on their own. When lock-out is used, the operator can use only the factory-set Automatic cycles and the one Custom cycle allowed per Select pad. Before using lock-out, create all desired Custom cycles.

To lock-out, hold SIGNAL pad and press MORE in the idle mode.

To unlock, hold SIGNAL pad and press LESS in the idle mode.

TEMPERATURE ADJUSTMENT

Selecting a fabric type selects a preset ideal temperature for that fabric. Lower temperatures may be needed for small loads or when airflow through the tumbler is less than ideal due to inadequate make-up air or exhaust ducting.

Whenever the control is on, but not in NO HEAT, COOL DOWN or LOAD READY, pressing the TEMP pad displays the three digits of the set temperature. Use the MORE or LESS pad to increase or decrease the temperature.

To select between Fahrenheit and Celsius display, hold in the TEMP DISPLAY pad while pressing the TEMP pad.

Fabric

MaximumMinimum
Selection

Preset Temp

Temp

 

 

 

COTTONS

180° F, 82° C

160° F, 71° C

 

 

 

PERM PRESS

160° F, 71° C

140° F, 60° C

 

 

 

MIXED

140° F, 60° C

120° F, 49° C

 

 

 

DELICATES

120° F, 49° C

100° F, 38° C

 

 

 

Temperature Setting Ranges

Table 11

NOTE: Temperature can be set from 80°F (27°C) to 180°F (82°C) in the Special Cycle and Special Time options only.

To include an adjusted temperature in a Custom cycle, simply adjust temperature before pressing CUSTOM.

SHOW MODE

This mode will show all LED’s and light up entire display while deactivating all pads. This mode allows loading door to be opened and closed. To enter this mode, the control must first be in the idle mode. Hold the START pad and press the SAVE CUSTOM pad. To exit Show Mode, hold the START pad and press the SAVE CUSTOM pad.

TEMPERATURE SENSOR

To test the temperature sensor, hold COOL DOWN pad and press the TEMP pad in the idle mode. This will show the temperature detected by the control.

“SH” displays and signal sounds if the temperature sensor is shorted or sensor temperature is over 200°F (93°C). Press the STOP/RESET pad twice within 3 seconds and allow the tumbler to cool, then press an ON/ SELECT pad. If “SH” still displays, call for service.

“OP” displays and signal sounds 3 minutes after the tumbler is started if the temperature sensor is faulty or if a temperature below 24°F (-4.4°C) is detected. If dryer temperature is above 24°F (-4.4°C), call for service.

NOTE: To display the software revision level, hold the AUTO pad and press the TIME pad while the control is in idle mode.

60

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

M414545