Chapter 8: Verifying the Hardware Operations of the Chassis
swplus# show version
AlliedWare Plus (TM) 5.4.2
Build name : |
| Software Version | |
| Number | ||
| |||
Build date : Wed Jun 2 12:13:19 NZDR 2013 | |||
| |||
Build type : RELEASE |
| ||
|
(c)1996,
.
.
.
Figure 131. SHOW VERSION Command
2.Compare the version number displayed by the SHOW VERSION command with the information in Table 19 on page 61 to confirm that the version of the AlliedWare Plus Operating System on the controller card supports all the hardware components in the chassis. If necessary, update the management software on the controller card.
3.To display the status of the power supplies, fan module, and AT- SBx81CFC400 Control Cards, use the SHOW SYSTEM ENVIRONMENT command in the User Exec or Privileged Exec mode. The Status column in the display provides the states of the modules. Components are operating normally when they have an “Ok” status.
4.To display the status of the line cards, use the SHOW CARD command in the Privileged Exec mode A line card has a state of “Online” when it is operating normally. An example of the status information is shown in Figure 132.
awplus# show | card |
| |
Slot | Card | Type | State |
1 | Online | |
2 | Online | |
3 | Online | |
4 | Online | |
5 | Online (Active) | |
6 | Online (Standby) | |
7 | Online | |
8 | Online | |
9 | Online | |
10 | Online | |
11 | Online | |
12 | Online |
Figure 132. SHOW CARD Command
184