Entering the
AlliedWare Plus
Operating System
Commands
SwitchBlade x8112 Chassis Switch Installation Guide
2.Connect the other end of the cable to an
3.Configure the
Baud rate: 115,200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow controller: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program.
4.Press Enter. You are prompted for a user name and password.
5.Enter the default user name and password. They are “manager” and “friend” (without the quotes), respectively
Note
User names and passwords are case sensitive.
The local management session starts and the command line interface (CLI) prompt is displayed.
To confirm the operations of the chassis with the commands in the AlliedWare Plus Operating System, perform the following procedure:
1.Enter the SHOW VERSION command in the User Exec or Privileged Exec mode to display the software version number of the management software on the controller card. An example of the command is shown in Figure 131 on page 184.
183