SwitchBlade x8112 Chassis Switch Installation Guide
167
Figure 121. Removing the Terminal Screws
6. With a #3 Phillips-head screwdriver, connect the positive (+) power
lead wire to the positive terminal on the power supply, with one of the
terminal screws removed in the previous step. The positive terminal is
on the left. Refer to Figure 122 on page 168.
Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.