SwitchBlade x8112 Chassis Switch Installation Guide
Table 28. Maximum Power Consumption (Continued)
48.3 W
Maximum power supply efficiency (based on 100V input voltage)
Table 29. Maximum Power Efficiency
Up to 90% | |
|
|
Up to 90% | |
|
|
Up to 90% | |
|
|
Heat dissipation (British Thermal Units/hour)
Table 30. | Heat Dissipation | |
|
|
|
| 146.72 BTU/hr | |
|
|
|
| 183.74 BTU/hr | |
|
|
|
| 146.72 BTU/hr | |
|
|
|
| 240.13 BTU/hr | |
|
|
|
| 233.73 BTU/hr | |
|
|
|
| 206.01 BTU/hr | |
|
|
|
| 5118.21 BTU/hr | |
|
|
|
| 5118.21 BTU/hr | |
|
|
|
| 5118.21 BTU/hr | |
|
|
|
Available Power over Ethernet (Watts/port):
Table 31. Available Power Over Ethernet with One PoE Power Supply
One PoE Power Supply Installed | 1200 W @ 56 VDC | |
|
|
|
IEEE 802.3at Class 4 | (30 W /port) | 40 ports Maximum |
|
| |
IEEE 802.3af Class 3 (15.4 W /port) | 77 ports Maximum | |
|
|
|
IEEE 802.3af Class 2 | (7.3 W /port) | 171 ports Maximum |
|
|
|
IEEE 802.3af Class 1 | (4.0 W /port) | 240 ports Maximum |
|
|
|
237