@PHT

Programming

Page Commands (Cont.)

@PHT

Syntax:

Set the hide effect

"'@PHT-<popup page name>;<hide effect time>'"

time for the

Variable:

specified popup

popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed

page.

On.

 

 

hide effect time = Given in 1/10ths of a second.

 

Example:

 

SEND_COMMAND Panel,"'@PHT-Popup1;50'"

 

Sets the Popup1 hide effect time to 5 seconds.

 

 

@PPA

If the page name is empty, the current page is used. Same as the ’Clear Page’ command

Close all popups

in TPDesign4.

 

on a specified

Syntax:

page.

"'@PPA-<page name>'"

 

 

Variable:

 

page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.

 

Example:

 

SEND_COMMAND Panel,"'@PPA-Page1'"

 

Close all popups on Page1.

 

 

@PPF

If the page name is empty, the current page is used (see example 2). If the popup page is

Deactivate a

part of a group, the whole group is deactivated. This command works in the same way as

the ’Hide Popup’ command in TPDesign4.

specific popup

 

page on either a

Syntax:

specified page or

"'@PPF-<popup page name>;<page name>'"

the current page.

Variable:

 

 

popup page name = 1 - 50 ASCII characters. Name of the popup page.

 

page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.

 

Example:

 

SEND_COMMAND Panel,"'@PPF-Popup1;Main'"

 

Example 2:

 

SEND_COMMAND Panel,"'@PPF-Popup1'"

 

Deactivates the popup page ’Popup1’ on the current page.

 

 

@PPG

If the page name is empty, the current page is used (see example 2). Toggling refers to the

Toggle a

activating/deactivating (On/Off) of a popup page. This command works in the same way

as the ’Toggle Popup’ command in TPDesign4.

specific popup

 

page on either a

Syntax:

specified page or

"'@PPG-<popup page name>;<page name>'"

the current page.

Variable:

 

 

popup page name = 1 - 50 ASCII characters. Name of the popup page.

 

page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.

 

Example:

 

SEND_COMMAND Panel,"'@PPG-Popup1;Main'"

 

Toggles the popup page ’Popup1’ on the ’Main’ page from one state to another (On/Off).

 

Example 2:

 

SEND_COMMAND Panel,"'@PPG-Popup1'"

 

Toggles the popup page ’Popup1’ on the current page from one state to another (On/Off).

 

 