Configuring Communications

As an example, if you use TECHPUBS as your SSID, you must match this word and the case within both the Network Name (SSID) field on the touch panel’s Network Name SSID field and on the WAP’s Basic Wireless Configuration page.

5.Toggle the Encryption field (FIG. 22) until it reads either: 64 Bit Key Size or 128 Bit Key Size. The 64/128 selection reflects the bit-level of encryption security. This WEP encryption level must match the encryption level being used on the WAP.

WEP will not work unless the same Default Key is set on both the panel and the Wireless Access Point.

For example: if you have your Wireless Access Point set to default key 4 (which was 01:02:03:04:05), you must set the panel’s key 4 to 01:02:03:04:05.

6.Toggle the Default Key field until the you’ve chosen a WEP Key value (from 1- 4) that matches what you’ll be using on your target WAP200G. This value MUST MATCH on both devices.

These WEP Key identifier values must match for both devices.

7.With the proper WEP Key value displayed, press the Generate button to launch the WEP Passphrase keyboard.

If you are wanting to have your target WAP (other than an NXA-WAP200G) generate the Current Key - Do not press the Generate button and continue with Step 13.

This keyboard allows you to enter a Passphrase (such as AMXPanel) and then AUTOMATICALLY generate a WEP key which is compatible only among all Modero panels.

The code key generator on Modero panels use the same key generation formula. Therefore, this same Passphrase generates identical keys when done on any Modero because they all use the same Modero-specific generator. The Passphrase generator is case sensitive.

8.Within this on-screen WEP Passphrase keyboard (FIG. 23), enter a character string or word (such as AMXPanel) and press Done when you have finished.

FIG. 23 WEP Passphrase Keyboard

MVP-8400i Modero Viewpoint Wireless Touch Panels

29

 

 

Page 39
Image 39
AMX MVP-8400i manual These WEP Key identifier values must match for both devices