Setup Pages

Batteries Page

The options on this page allow you to set power warning preferences, monitor battery status information, and adjust the display times for battery warnings. This page is populated with information from MVP- BP batteries in the panel, as well as batteries in a connected MVP-TDS/WDS docking station (FIG. 50).

FIG. 50 Batteries page

Features on this page include:

Batteries Page

Back:

Saves all changes and returns to the previous page.

 

 

Connection Status icon:

The icon in the upper-right corner of each Setup page shows online/offline state

 

of the panel to the master.

 

• Bright red - disconnected

 

• Bright green - connected. Blinks when a blink message is received to dark

 

green every 5 seconds for half a second then go back to bright green.

 

• Bright yellow - panel missed a blink message from the master. It will remain

 

yellow for 3 missed blink messages and then turn red. It will return to green

 

when a blink message is received.

 

Note: a Lock appears on the icon if the panel is connected to a secured NetLinx

 

Master.

 

 

Battery Power Brightness

The DISABLE/DISABLED button acts as a power save feature with two options:

Limit:

Disable - activates the brightness limit set on the panel (conserves battery

 

power). Activating this feature causes the panel to function at 80% of full

 

brightness and overrides the Panel Brightness value set on the Setup page.

 

Disabled - deactivates this power save feature. The panel will use the Panel

 

Brightness level.

 

Note: This field applies to MVP-BP batteries installed in the panel.

 

 

Panel Shutdown:

This value determines the number of minutes that would need to pass before

 

the panel automatically shuts-down. Once shutdown, the unit would have to be

 

restarted. The UP/DN buttons alter the timeout value (in minutes). A value of 0

 

disables this feature.

 

Range = 0 - 240, default = 1200 min.

 

Note: This field applies to MVP-BP batteries installed in the panel.

 

 