AMX MVP-8400i manual G4 Web Control Page, Setup Pages, Back, Connection Status icon, Master

Models: MVP-8400i

1 198
Download 198 pages 7.68 Kb
Page 76
Image 76
G4 Web Control Page

Setup Pages

Features on this page include:

G4 Web Control Page

Back:

Saves all changes and returns to the previous page.

 

 

Connection Status icon:

The icon in the upper-right corner of each Setup page shows online/offline state

 

of the panel to the master.

 

• Bright red - disconnected

 

• Bright green - connected. Blinks when a blink message is received to dark

 

green every 5 seconds for half a second then go back to bright green.

 

• Bright yellow - panel missed a blink message from the master. It will remain

 

yellow for 3 missed blink messages and then turn red. It will return to green

 

when a blink message is received.

 

Note: a Lock appears on the icon if the panel is connected to a secured NetLinx

 

Master.

 

 

G4 Web Control Settings:

Sets the IP communication values for the touch panel:

Enable/Enabled

 

The Enable/Enabled button allows you to toggle between the two G4 activation

 

settings:

 

Enable - deactivates G4 Web Control on the panel.

 

Enabled - activates G4 Web Control on the panel.

Network Interface Select

 

Displays “Wireless” when the panel is communicating via a Wireless Access

 

Point (WAP).

Web Control Name

 

Use this field to enter a unique alpha-numeric string to be used as the panel’s

 

display name within the Manage WebControl Connections window of the

 

NetLinx Security browser window.

Web Control Password

 

Use this field to enter the G4 Authentication session password required for

 

VNC access to the panel.

Web Control Port

 

Enter the number of the port used by the VNC Web Server. Default = 5900.

 

 

Maximum Number of

Displays the maximum number of users that can be simultaneously connected

Connections

to this panel via VNC. Default = 1.

Current Connection Count

 

Displays the number of users currently connected to this panel via VNC.

 

 

G4 Web Control Timeout:

Sets the length of time (in minutes) that the panel can remain idle (no cursor

 

movements) before the G4 Web Control session is terminated.

 

• Minimum value = 0 minutes (panel never times out)

 

• Maximum value = 240 minutes (panel times out after 240 minutes)

 

 

Refer to the Using G4 Web Control to Interact with a G4 Panel section on page 38 for instructions on using the G4 Web Control page with the web-based NetLinx Security application.

66

MVP-8400i Modero Viewpoint Wireless Touch Panels

Page 76
Image 76
AMX MVP-8400i manual G4 Web Control Page, Setup Pages, Back, Connection Status icon, Master, G4 Web Control Settings