Upgrading MVP Firmware

Showing the Virtual Master firmware version and device number

Shows NetLinx Studio version number

Showing the current MVP panel firmware version and device number

FIG. 37 NetLinx Workspace window (showing panel connection via a Virtual NetLinx Master)

The panel-specific firmware is shown on the right of the listed panel.

Download the latest firmware file from www.amx.com and then save the Kit file to your computer. Note that each kit file is intended for download to its corresponding panel.

5.If the panel firmware version is not the latest available; locate the latest firmware file from the www.amx.com > Tech Center > Downloadable Files > Firmware Files > Modero Panels section of the website.

6.Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you have downloaded the Modero Kit file to a known location.

7.Select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (B in FIG. 38). Verify the panel’s System and Device number values match those values listed within the System folder in the OnLine Tree tab of the Workspace window (A in FIG. 38).

A

B

FIG. 38 Using USB for a Virtual Master transfer

8.Select the panel’s Kit file from the Files section.

9.Enter the Device value associated with the panel and the System number associated with the Master (listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.

46

MVP-8400i Modero Viewpoint Wireless Touch Panels

Page 56
Image 56
AMX MVP-8400i manual Using USB for a Virtual Master transfer