Programming

Button Query Commands (Cont.)

?BCF

Syntax:

Get the current fill

"'?BCF-<vt addr range>,<button states range>'"

color.

Variable:

 

 

variable text address range = 1 - 4000.

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

custom event type 1012:

 

Flag - Zero

 

Value1 - Button state number

 

Value2 - Actual length of string (should be 9)

 

Value3 - Zero

 

Text - Hex encoded color value (ex: #000000FF)

 

Text length - Color name length (should be 9)

 

Example:

 

SEND COMMAND Panel,"'?BCF-529,1'"

 

Gets the button 'OFF state' fill color information.

 

The result sent to the Master would be:

 

ButtonGet Id = 529 Type = 1012

 

Flag = 0

 

VALUE1 = 1

 

VALUE2 = 9

 

VALUE3 = 0

 

TEXT = #FF8000FF

 

TEXT LENGTH = 9

 

 

?BCT

Syntax:

Get the current

"'?BCT-<vt addr range>,<button states range>'"

text color.

Variable:

 

 

variable text address range = 1 - 4000.

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

custom event type 1013:

 

Flag - Zero

 

Value1 - Button state number

 

Value2 - Actual length of string (should be 9)

 

Value3 - Zero

 

Text - Hex encoded color value (ex: #000000FF)

 

Text length - Color name length (should be 9)

 

Example:

 

SEND COMMAND Panel,"'?BCT-529,1'"

 

Gets the button 'OFF state' text color information.

 

The result sent to Master would be:

 

ButtonGet Id = 529 Type = 1013

 

Flag = 0

 

VALUE1 = 1

 

VALUE2 = 9

 

VALUE3 = 0

 

TEXT = #FFFFFEFF

 

TEXT LENGTH = 9

 

 

MVP-8400i Modero Viewpoint Wireless Touch Panels

135

 

 

Page 145
Image 145
AMX MVP-8400i manual ?Bcf, ?Bct