Quick Guide

however be at least four T-stops apart, in order to define the iris table.

If the iris scale is not linear, all the T-stops must be programmed.

After programming the iris table, the T-stops on the iris ring of the lens must be controlled by adjusting with the handwheel and visually checking the lens.

If the created iris table should remain available for later use, it must be stored. This also applies when an iris table has been re-edited.

Storing iris tables:

The handwheel must then be turned in the table menu (TBL LOAD, TBL DEL, TBL EDIT, TBL STORE) until ‘STORE’ is displayed in the second line.

Confirm the selection by pressing the SEL button – ‘STORE’ is displayed in the first line,

and the number of the memory area is shown in the second line (10 memory areas are available).

Select the number of the required memory area using the handwheel and store the iris table by pressing the SEL button.

Note down the number of the memory area together with the programmed lens to simplify activating lenses at a later time.

176