Setup

locking lever

tube

receptacle

ballcatch

Setup with Iris control

A CLM-2 motor must be mounted if the iris of the lens is to be controlled by the WRC-1.

Mounting the CLM-2 motor with/without console

Console order number: K2.52035.0

Flip up the locking lever photo and screw back the ballcatch photo with a screwdriver until it disappears completely in the bracket.

Push the tube photo flush into the console recep- tacle, taking care that the slit in the tube points to- wards the ballcatch.

Screw the ballcatch out of the bracket until the tube can no longer be pushed out of the bracket.

Turn the locking lever until a slight resistance can be felt, then press the lever downwards.

Fasten the motor unit CLM-2 to the console tube.

22