Baud Rate

Wallboard Installation and Maintenance

INDeX Wallboard 10

Baud Rate

The Baud Rate can be changed to 1200, 2400, 9600 or 19200 using the dip-switch. The Baud Rate is set using switches 5 and 6.

5

6

Baud Rate

ON

ON

1200

 

 

 

OFF

ON

2400

 

 

 

ON

OFF

9600

 

 

 

OFF

OFF

19200

 

 

 

 

 

 

Ensure the Baud rate is set to 9600.

Test Functions

Test functions are provided to assist installation engineers. These are selected on the dips-witches. Test functions are selected using switches 7 and 8.

If switch 7 and 8 are OFF at power reset:

7

8

 

ON

ON

Freeze Display

 

 

 

OFF

ON

Alternating ON/OFF Blocks of LED's

 

 

 

ON

OFF

Stripes

 

 

 

OFF

OFF

Normal Operation

 

 

 

 

 

 

If switch 7 and 8 are ON at a power reset:

7

8

 

ON

ON

Information Screen

 

 

 

OFF

ON

Stripes

 

 

 

ON

OFF

Alternating ON/OFF Blocks of LED's

 

 

 

OFF

OFF

Freeze Display

 

 

 

 

 

 