Bosch Appliances VEZ installation manual O-ring and retaining ring for outdoor installation

Models: VEZ

1 144
Download 144 pages 63.57 Kb
Page 57
Image 57

AutoDome Easy II IP

 

 

 

 

Installing a Pipe Mount en 57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7.4 O-ring and retaining ring for outdoor installation

1O-ring; 21.82 mm I.D. by Ø3.00 mm

2 Dome Cap

3 Retaining ring with gasket

4 M3 – .5 x 6 Phillips flat head machine screws

a.Thread the 21.82 mm I.D. by Ø3.00 mm O-ring (item 1, above) onto the lower pipe threads.

b.Secure the retaining ring gasket (item 2, above) to the dome cap with the three (3) M3 – .5 x 6 Phillips flat head machine screws. Ensure that the side of the retaining ring with the counter-sunk screw holes is facing you.

8.Secure the flange using four (4) appropriate user-provided fasteners such as Moly or Toggle bolts.

Outdoor Installation: Place the flat gasket (item 1, below) between the flange and the surface before securing.

Bosch Security Systems, Inc.

Installation Manual

F.01U.164.576 2.0 2010.03

Page 57
Image 57
Bosch Appliances VEZ installation manual O-ring and retaining ring for outdoor installation