9.2.2Connecting a Normally Closed Alarm

1.Connect the alarm to the appropriate input (1 through 2) and ground at the AutoDome Easy II.

Figure 9.3 N.C. Normally Closed Connections

Ref. #

User Contact

Dome

Color

1

Normally

Alarm In 1 or Alarm In 2

Brown IN 1 or

 

Closed

(Ref. #3)

Orange IN 2

 

 

 

 

2

Common

Ground (Ref. #4)

Green

2.From the AutoDome Easy II main menu select Alarm Setup>Inputs Setup, and set Alarm Input # to N.C. See the table below for contact and condition details.

AutoDome Easy II Programmed N.C.

Circuit

Open

Closed

Alarm Indication

Alarm

Normal