66 en Preparing the Wiring | AutoDome Easy II IP |
|
|
8.2.2Power Connections to Outdoor Cameras
NOTICE! The AutoDome Easy II IP outdoor camera cannot be powered via Power over Ethernet. You must supply a 24 VAC power supply to the camera.
Figure 8.2 Power Cable
| Ref. # | Wire | Color |
| 1 | 24 VAC | Red |
| 2 | 24 VAC | Black |
| 3 | User supplied Power Supply | n/a |
|
|
|
|
WARNING!
The camera unit accepts 24 VAC, 1.2 A power only. Do not connect 120 V or 230 V to this camera.
To connect the power to outdoor models:
1.Locate the cable assembly with a three (3) pin mating connector on one end and the red and black flying leads on the other end.
2.Connect one lead of the 24 VAC power source to the black wire.
3.Connect the other lead of the 24 VAC power source to the red wire.
4.Connect the green earth ground cable to a suitable grounded conduit.
F.01U.164.576 2.0 2010.03 | Installation Manual | Bosch Security Systems, Inc. |