Bosch Appliances VEZ installation manual Ethernet Connection IP models

Models: VEZ

1 144
Download 144 pages 63.57 Kb
Page 67
Image 67

AutoDome Easy II IP

Preparing the Wiring en 67

 

 

8.2.3Power Connections to Heater (all outdoor models)

Figure 8.3 Power Cable

 

Ref. #

Wire

Color

 

1

24 VAC

White/Red

 

2

24 VAC

White/Black

 

3

User supplied Power Supply

n/a

 

 

 

 

WARNING!

The heater unit accepts 24 VAC, 2 A power only. Do not connect 120 V or 230 V to this heater.

To connect the power to outdoor heaters:

1.Locate the cable assembly with a three (3) pin mating connector on one end and the white/red and white/black flying leads on the other end.

2.Connect one lead of the ground or 24 VAC power source to the white/black wire.

3.Connect one lead of the 24 VAC power source to the white/red wire.

8.3Ethernet Connection (IP models)

The AutoDome Easy II IP connects to a 10 Base-T/100 Base-TX network either directly or via a hub. Both video and control are transmitted over a standard TCP/IP network using the built-in Web server. In addition, power can be supplied to indoor IP camera models via the Ethernet cable compliant with the Power-over-Ethernet (IEEE 802.3af) standard.

Refer to Section 11 Using the AutoDome Easy II IP, page 74, for instructions on configuring an IP environment.

CAUTION!

Ethernet connections must be made to non-exposed (indoor) networks only.

Bosch Security Systems, Inc.

Installation Manual

F.01U.164.576 2.0 2010.03

Page 67
Image 67
Bosch Appliances VEZ installation manual Ethernet Connection IP models, Power Connections to Heater all outdoor models