Bosch Appliances VEZ installation manual Preparing the Wiring, Power

Models: VEZ

1 144
Download 144 pages 63.57 Kb
Page 63
Image 63

AutoDome Easy II IP

Preparing the Wiring en 63

 

 

8Preparing the Wiring

The wiring requirements for the various AutoDome Easy II models differ slightly. There are four (4) types of wires: control, video, power, and alarm, and each model has different wiring requirements. Each section provides the specifications for the recommended wire.

CAUTION!

Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes.

CAUTION!

All wires for installation applications must be routed through a grounded conduit.

8.1Power

The recommended power cable is a 2-conductor, 14-18 gage cable, depending on the distance.

 

 

VA / Watts

14 AWG

16 AWG

18 AWG

 

 

 

 

(2.5 mm)

(1.5 mm)

(1.0 mm)

 

 

 

 

 

 

Camera, Indoor models

 

 

 

 

 

 

 

 

 

 

 

24

VAC to AutoDome Easy II

18

/ 10

632 ft

398 ft

250 ft

 

 

 

 

(193 m)

(121 m)

(76 m)

 

 

 

 

 

 

12 VDC to AutoDome Easy II

10

W

285 ft

179 ft

112 ft

 

 

 

 

(87 m)

(55 m)

(34 m)

 

 

 

 

 

Camera and Heater, Outdoor

models only

 

 

 

 

 

 

 

 

24

VAC to AutoDome Easy II

18

/ 10

632 ft

398 ft

250 ft

 

 

 

 

(193 m)

(121 m)

(76 m)

 

 

 

 

 

 

 

24

VAC to Heater

25

/ 25

455 ft

287 ft

180 ft

 

 

 

 

(139 m)

(67 m)

(55 m)

 

 

 

 

 

 

 

Table 8.1 Max. Wire Distances from Power Supply to AutoDome Easy II