Bosch Appliances VEZ Alarms and Relay Connections, Alarm Input, Wire Color Function

Models: VEZ

1 144
Download 144 pages 63.57 Kb
Page 69
Image 69

AutoDome Easy II IP

Alarms and Relay Connections en 69

 

 

9Alarms and Relay Connections

9.1Alarm Input

The AutoDome Easy II provides two alarm inputs. Each input can be activated by dry contact devices such as pressure pads, passive infrared detectors, door contacts, and similar devices. The AutoDome Easy II comes with the following alarm in/out cable.

Figure 9.1 Four-wire Alarm In/Out Cable

Wire Color

Function

White

Alarm Out

Brown

Alarm In 1

Orange

Alarm In 2

Green

Ground

The table below summarizes the size and distance wires.

Wire Size

Maximum Distance

 

 

 

 

AWG

 

mm

feet

meters

 

 

 

 

 

22

 

0.644

500

152.4

 

 

 

 

 

18

 

1.024

800

243.8

 

 

 

 

 

Table 9.1

Alarm Wire Guide

 

You wire alarms either Normally Open (N.O.) or Normally Closed (N.C.), and must program the alarm inputs N.O. (the default) or N.C. through the AutoDome Easy II main menu.

Bosch Security Systems, Inc.

Installation Manual

F.01U.164.576 2.0 2010.03

Page 69
Image 69
Bosch Appliances VEZ Alarms and Relay Connections, Alarm Input, Wire Color Function, Wire Size Maximum Distance