8. ELECTRIC MECHANISM

Error status

#1

The power indicator does not light when the power is turned on.

 

 

 

 

 

 

 

 

 

Probable causes

 

Check/ repair/ adjust

Parts to be replaced

1.

Conversion

transformer

Note: Before adjustment, be sure to check

 

 

improperly wired

 

that the power is turned off to prevent

 

 

(for

100V

and 110V

 

electric shock.

 

 

 

 

 

specifications)

 

If the power is turned on, turn off the

 

 

 

 

 

 

power, and wait at least 5 minutes.

 

 

 

 

 

• Conversion in the control box

 

 

 

 

 

 

Check the transformer is correctly and

 

 

 

 

 

 

securely wired to the terminals.

 

 

 

 

 

 

(For 200V, 220V and 230V specifications,

 

 

 

 

3630Q

 

this is not necessary.)

 

 

 

 

 

 

<100V>

 

 

 

 

 

 

 

(for 240V, 380V, 400V and

 

 

 

 

 

 

 

415V specifications)

 

 

 

 

 

 

 

 

 

3631Q

 

 

 

 

 

 

 

 

 

<400V>

 

 

 

 

 

 

(for 200V, 220V and 230V

 

 

 

 

 

 

specifications)

 

 

 

 

 

 

 

No

conversion

transformer is

 

 

 

 

 

 

installed.

 

 

 

 

 

 

 

 

2.

Conversion

transformer

• Separate P4 (ACIN) connectors on the

Conversion transformer

 

defective

 

 

power supply circuit board, and check

 

 

 

 

 

 

there is continuity between pins 1 and 2 in

 

 

 

 

 

 

the connector on the cable.

 

 

 

 

 

 

(For 200V, 220V and 230V specifications,

 

 

 

 

 

 

this is not necessary.)

 

 

 

 

 

 

3632Q

 

 

 

 

 

 

 

 

 

 

 

 

3. Power supply cable defective

• Separate P4 (ACIN) connectors on the

Power supply cable

 

 

 

 

 

power supply circuit board, turn on the

 

 

 

 

 

 

power, and measure the voltage across

 

 

 

 

 

 

pins 1 and 2 in the connector on the cable.

 

 

 

 

 

 

If the voltage is as shown in the table below,

 

 

 

 

 

 

the power supply cable is not defective.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For 200V, 220V and

 

The same as the

 

 

 

 

 

 

power supply voltage

 

 

 

 

 

 

 

230V specifications

 

 

 

 

 

 

 

 

of wall socket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For 100V, 110V,

 

 

 

 

 

 

 

 

 

240V, 380V, 400V

 

About 220V

 

 

 

 

 

 

 

and 415V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specifications

 

 

 

 

 

 

 

3633Q

After checking, turn off the power, and rejoin

 

 

 

 

P4 connectors.

 

 

 

 

4. Fuse has blown

• Remove fuses No.3 and No.4, and check

Fuse 6A-250V

 

 

 

 

 

them for continuity.

 

 

 

 

 

 

 

 

 

If there is no continuity, replace the fuses

 

 

 

 

 

 

with new ones, and perform the check/

 

 

 

 

 

 

repair/ adjust items of #1-5.

 

177

KE-430B, 430C series