| 8. ELECTRIC MECHANISM |
| |
|
|
|
|
|
| ||||
|
|
|
|
|
| ||||
| Error status | #8 Error code appears on the display window when the foot switch is depressed. |
| ||||||
|
|
|
|
|
|
| |||
| Probable causes |
| Check/ repair/ adjust |
| Parts to be replaced |
| |||
| 2. Power supply circuit board is | a. Measure the resistance between the fuse |
| Power supply circuit |
| ||||
| defective |
| when | the | feed | No.1 terminal which is close to the center |
| board |
|
| mechanism | does | not | move | of the power supply circuit board and pin |
|
|
| |
| and error code | 2 of P5 (DC300) connector. |
|
|
| ||||
| on the display window. |
| If the resistance is ∞ Ω, the power supply |
|
|
| |||
| ([E.A1] | circuit board is not defective. |
|
|
| ||||
|
|
|
|
|
| b. Separate P9 (POWER) connectors on the |
|
|
|
|
|
|
|
|
| main circuit board, turn on the power, and |
|
|
|
|
|
|
|
|
| measure the voltage across the following |
|
|
|
|
|
|
|
|
| pairs of pins, pins 4 and 6 and pins 5 and |
|
|
|
|
|
|
|
|
| 7, in the connector on the cord. |
|
|
|
|
|
|
|
|
| If the voltage is +55V in each case, the |
|
|
|
|
|
|
|
|
| power supply circuit board is not |
|
|
|
|
|
|
|
|
| defective. |
|
|
|
|
|
|
|
|
| After measurement, turn off the power, |
|
|
|
|
|
|
|
|
| wait at least 5 minutes, and rejoin P9 |
|
|
|
|
|
|
|
|
| connectors. |
|
|
|
|
|
|
|
|
| c. Separate P9 (POWER) connectors on the |
|
|
|
|
|
|
|
|
| main circuit board, turn on the power, and |
|
|
|
|
|
|
|
|
| measure the voltage across pins 2 and 3 |
|
|
|
|
|
|
|
|
| on the cord. |
|
|
|
|
|
|
|
|
| If it is + 24V, the power supply circuit |
|
|
|
|
|
|
|
|
| board is not defective. |
|
|
|
|
|
|
|
|
| After measurement, turn off the power, |
|
|
|
|
|
|
|
|
| wait at least 5 minutes, and rejoin P9 |
|
|
|
|
|
|
|
| 3638Q | connectors. |
|
|
|
| 3. Home position sensor is defec- | a. Turn the poewr switch off and then on |
| Home position sensor |
| ||||
| tive when the work clamp | again, and move the work clamp to near |
|
|
| ||||
| moves | in | an | unexpected | the home position by hand. |
|
|
| |
| direction and error code | If the home position sensor LED is lit, the |
|
|
| ||||
| appears on the display window. | home position sensor is not defective. |
|
|
| ||||
| ([E.A1] | b. Check that P1 (ORG) connector on the |
|
|
| ||||
|
|
|
|
|
| main circuit board and the home position |
|
|
|
|
|
|
|
|
| sensor are plugged in. |
|
|
|
|
|
|
|
|
| c. See |
| Main circuit board |
|
|
|
|
|
|
| DIP switch input” to make sure that the |
|
|
|
|
|
|
|
|
| home position sensor is connected. |
|
|
|
|
|
|
|
|
| If item a causes no problem and item b |
|
|
|
|
|
|
|
|
| results in defective sensor input, either |
|
|
|
|
|
|
|
|
| the cord connection is poor or the main |
|
|
|
|
|
|
|
|
| circuit board is defective. |
|
|
|
|
|
|
|
|
| ||||
| 4. Pulse motor and cord are | a. Separate P6 (YPM) and P7 (XPM) |
| X- or |
| ||||
| defective | when | the | work | connectors on the main circuit board. |
| assembly |
| |
| clamp operates | abnormally | Measure the resistance between the |
|
|
| |||
| and error code | following pairs of pins, pins 4 and 6 and |
|
|
| ||||
| on the display window. |
| pins 5 and 7, in the connector on the |
|
|
| |||
| ([E.A1] | cord. |
| Main circuit board |
| ||||
|
|
|
|
|
| If the resistance is |
|
| |
|
|
|
|
|
| defective. |
|
|
|
|
|
|
|
|
| After measurement, rejoin P6 and P7 |
|
|
|
|
|
|
|
|
| connectors. |
|
|
|
|
|
|
|
|
| b. If item a causes no problem, the main |
|
|
|
|
|
|
|
|
| circuit board is defective. |
|
|
|
|
|
|
|
| 3639Q |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
182 |