8. ELECTRIC MECHANISM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error status

#1

The power indicator does not light when the power is turned on.

 

 

 

 

 

 

 

 

 

 

 

Probable causes

 

Check/ repair/ adjust

 

Parts to be replaced

 

 

5. Power supply circuit board

• Separate P4 (ACIN) connectors on the

 

Power supply circuit

 

 

defective

 

 

 

power supply circuit board, and then

 

board

 

 

 

 

 

 

measure the resistance between the

 

 

 

 

 

 

 

 

following pairs of pins, pins 1 and 4 and

 

 

 

 

 

 

 

 

pins 2 and 4, in the connector on the

 

 

 

 

 

 

 

 

cable.

 

 

 

 

 

 

 

 

If the resistance is ∞ Ω in both cases, the

 

 

 

 

 

 

 

 

power supply circuit board is not defective.

 

 

 

 

 

 

 

• Measure the resistance between pins 1

 

 

 

 

 

 

 

 

and 2.

 

 

 

 

 

 

 

 

If there is no short, the power supply

 

 

 

 

 

 

 

 

circuit board is not defective.

 

 

 

 

 

 

 

• Rejoin P4 (ACIN) connectors on the

 

 

 

 

 

 

 

 

power supply circuit board.

 

 

 

 

 

 

 

 

Separate P9 (POWER) connectors on the

 

 

 

 

 

 

 

 

main circuit board, turn on the power, and

 

 

 

 

 

 

 

 

measure the voltage across pins 1 and 3

 

 

 

 

 

 

 

 

in the connector on the cable.

 

 

 

 

 

 

 

 

If it is + 5V, the power circuit board is not

 

 

 

 

 

 

 

 

defective.

 

 

 

 

 

 

 

 

After measurement, turn off the power,

 

 

 

 

 

 

 

 

wait at least 5 minutes, and then rejoin P9

 

 

 

 

 

 

3634Q

 

connectors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Main circuit board defective

With P9 (POWER) connectors plugged in

 

Main circuit board

 

 

 

 

 

 

on the main circuit board, turn on the

 

 

 

 

 

 

 

 

power, and measure the voltage across

 

 

 

 

 

 

 

 

pins 1 and 3 in the connector on the cable.

 

 

 

 

 

 

 

 

If it is + 5V, the power circuit board is not

 

 

 

 

 

 

 

 

defective.

 

 

 

 

 

 

 

 

After measurement, turn off the power.

 

 

 

 

 

 

3635Q

 

 

 

 

 

 

7. Panel circuit board defective

Check that P8 (PANEL) connectors of the

 

Panel circuit board

 

 

 

 

 

 

main circuit board and P1 (PANEL)

 

Panel cord

 

 

 

 

 

 

connectors of the panel circuit board are

 

 

 

 

 

 

 

 

plugged in.

 

 

 

 

 

 

 

<KE-436B, 436C>

 

Panel circuit board

 

 

 

 

 

Check that P20 (RSPORT) connectors of

 

 

 

 

 

 

 

 

the main circuit board and P5 (DRV)

 

 

 

 

 

 

 

 

connectors of the panel circuit board are

 

 

 

 

 

 

 

 

plugged in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error status

#2

Error code appears on the display window when the power is turned on.

 

 

 

 

 

 

 

 

 

Probable causes

 

Check/ repair/ adjust

 

Parts to be replaced

 

 

1. Cooling fan defective when

a. Check threads are not tangled in the

 

DC fan motor assembly

 

 

the error code E-70 appears

 

cooling fan.

 

 

 

 

on the display window.

b. Check P10 (FAN) connectors are

 

 

 

 

([E.c1] KE-436B, 436C)

 

securely plugged in on the main circuit

 

 

 

 

 

 

 

 

board.

 

 

 

 

 

 

 

 

 

 

 

 

KE-430B, 430C series

178