8. ELECTRIC MECHANISM

Error status

#20

The machine does not stop with the needle at the upper position.

 

 

 

 

(“E-50” appears <“E.22” for the KE-436B and 436C>.)

 

 

 

 

 

 

 

 

Probable causes

 

Check/ repair/ adjust

 

Parts to be replaced

3.

Cord defective

 

See #15-1.

 

 

 

 

 

 

 

 

 

4.

Power

supply

circuit board

• With P13 (DC18) connectors plugged in

 

Power supply circuit

 

defective

 

 

on the main circuit board, measure the

 

board

 

 

 

 

 

voltage in the connector on the cable.

 

 

 

Main circuit board

 

 

If the voltage across the following pairs of

 

 

 

 

 

pins, pins 1 and 2, pins 4 and 5, and pins

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 and 11 is DC 15–18 V, it is OK.

 

 

 

+15 – 18V for each

 

 

 

 

 

 

 

3651Q

 

 

 

 

 

 

 

 

 

 

5.

Main circuit board defective

 

 

 

Main circuit board

 

 

 

 

 

 

 

6.

Motor defective

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

Error status

#21

Programming can not be made. (KE-436B, 436C only)

 

 

 

 

 

 

 

 

Probable causes

 

Check/ repair/ adjust

 

Parts to be replaced

1.

The programmer connector

• Remove connector P2 (PGM) on the

 

 

 

and its cable are defective.

 

panel PCB and connector P2 on the

 

 

 

 

 

 

 

programmer PCB, and then return them to

 

 

 

 

 

 

 

their positions.

 

 

 

 

 

 

 

2.

The programmer is defective.

• Replace the programmer with a new one.

 

Programmer

 

 

 

 

 

 

3.

Panel circuit board defective

Replace the panel circuit board with a new

 

Panel circuit board

 

 

 

 

 

one.

 

 

 

 

 

 

 

 

 

 

189

KE-430B, 430C series