Cabletron Systems 9A000 manual Installing the Rack-mount Brackets, Switch Setup

Models: 9A000

1 180
Download 180 pages 32.99 Kb
Page 58
Image 58
4.5.2Installing the Rack-mount Brackets

Switch Setup

4.5.2Installing the Rack-mount Brackets

To install the rack-mount brackets and cable relief strain rail, use the follow- ing procedure:

1.Carefully place the SFCS-200WG unit upside down on a clean, flat, sturdy work surface with the front of the unit still facing front.

2.Using a Phillips screwdriver, remove the four feet from the bottom of the unit.

3.Each rack-mount bracket has three screws that secure the bracket to the bottom of the unit. The screw closest to the front of the unit is used to secure the bracket to the bottom of the unit as well as secure the cable relief strain rail to the front of the unit. Tighten the three screws to secure the left bracket, marked HWST0027-0001, and the left side of the cable relief strain rail to the left side of the unit. Tighten the three screws to secure the right bracket, marked HWST0027-0002, and the right side of the cable relief strain rail to the right side of the unit.

CAUTION When attaching the rack-mount brackets, the use of screws other than those provided could result in damage to the unit.

4.Once the brackets and the cable relief strain rail are secure, choose a rack position for the SFCS-200WG. The SFCS-200WG should be placed right side up in the rack with the front of the unit facing forward.

CAUTION When it is mounted in the equipment rack, do not use the SFCS-200WG chassis to support Manual backgroundother equipment. This could overload the Manual backgroundmounting brackets and cause damage to the

unit.

4-8

Page 58
Image 58
Cabletron Systems 9A000 manual Installing the Rack-mount Brackets, Switch Setup