7.Ensure that the fuses on the new unit are rated at 12.5A, 250V.

Hardware Maintenance Procedures

WARNING! Failure to perform Steps 6 or 7 can result in serious injury to the user or damage to the equipment.

6.Ensure that the power switch on the new power supply is turned OFF before inserting it into the enclosure.

7.Ensure that the fuses on the new unit are rated at 12.5A, 250V.

8.Carefully align the guide rails on the new AC power supply in the slot.

9.Push on the center of the front panel of the power supply to slide it back into the enclosure.

10.To ensure maximum safety and to ensure that the connectors have been seated properly, re-tighten the four retaining screws using a 3/32-inch Allen wrench.

11.Reconnect and plug in the power cord to the new power supply.

12.Turn the power switch on the new supply to the ON position.

5-8