TEMP
Temperature inquiry
Format
| GET□TEMP |
|
|
|
|
|
| |||
<n> | Number | 0 to 255 | ||||||||
<v> | ||||||||||
Temperature value | 0.0 to 127.9 °C | |||||||||
| ||||||||||
Environment |
|
|
|
|
|
| ||||
| Power |
|
|
|
| Input | ||||
OFF | ON | PM | COMP | VIDEO | HDMI | None | ||||
X | O | X |
| - |
|
|
|
Response
Temperature is returned as 'g:TEMP=<n>{,<v>}'
For details on other responses, refer to the "Error List".
Description
(1)This inquires about the temperature sensor value.
(2)Number of temperature sensors varies according to model.
(3)When returning multiple temperature sensor values, values will be separated with a comma. There are cases when a number of sensors is 0. In this case, there will not be a comma.
(4)For correspondence of temperature sensor sequence and actual installation location, inquire separately.
Example
Setting
None |
|
Reference | This retrieves the temperature sensor values. |
> GET TEMP |
<g:TEMP=5,37.1,63.0,38.9,29.7,32.4
*Commands are indicated by ">", and responses are indicated by "<".
Revision History / Date
Changes
Revised by
Approved by
- 73 -