Canon Track, The tracking adjustment value is set to, Projector WUX10 MarkII User Commands

Models: WUX10

1 91
Download 91 pages 20.64 Kb
Page 79
Image 79
TRACK

Projector WUX10 MarkII User Commands

TRACK

Tracking adjustment

The tracking adjustment value is set to 25. Format

TRACK=<Adjustment value:Number>

GETTRACK / ?TRACK

Manual background Environment

 

Power

 

 

 

 

Input

 

 

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

COMP

VIDEO

HDMI

None

X

O

X

X

O

O

X

X

X

X

Manual background Response

"i:OK" is returned if the parameter was set properly.

For 'GET TRACK' or '?TRACK', current tracking adjustment value is returned as 'g:TRACK=<Adjustment value:Number>'

For details on other responses, refer to the "Error List".

Manual background Description

(1)This is used for adjustment when tracking (synchronization) is out of sync and the screen flickers.

(2)This command functions in the same way as when "Display setting" - "Input signal selection" - "Tracking adjustment" are selected on the menu.

(3)If the input is neither "A-RGB1" nor "A-RGB2", 'e:200X INVALID_SOURCE(***)' is returned as an error response.

(4)If signals are not input, 'e:2010 NO_SIGNAL' is returned.

(5)Adjustment range is limited. If number is invalid, "e:0801 INVALID_VALUE" is returned.

(6)The GET command can be used to retrieve the current tracking adjustment values. ("GET TRACK")

Manual background Example

Setting

>

TRACK=25

The tracking adjustment value is set to 25.

<

i:OK

 

Reference

>GET TRACK or ?TRACK This retrieves the tracking adjustment setting value.

< g:TRACK=21

*Commands are indicated by ">", and responses are indicated by "<".