Chapter 9 First-Time Setup

Loading CTS Administration Software

Note Make sure that you power on all codecs within 30 seconds to avoid power on detection failure.

After you turn on the codecs, the displays associated with each codec becomes active. CTS displays green check marks on all displays to show bootup progress. Bootup is complete when the system displays six check marks as shown in Figure 9-1.

Figure 9-1 Bootup Completed

Note If the last check mark displayed is a red “X,” there has been a compact flash error. Please contact Cisco Technical Support.

After bootup completes, make a note of the IP address that displays on the center of the screen as shown in Figure 9-2. You use that information to log in to the Cisco TelePresence System Administration. This IP address displays until you log in to Cisco TelePresence System Administration or use Secure Shell (SSH) to log in to the CTS-3000.

Cisco TelePresence System 3000

9-2

OL-14521-01

 

 