11-20
Cisco TelePresence System 3000
OL-14521-01
Chapter 11 Field-Replaceable Unit Guide
Replacing a PDU—Part Number CTS-PWR-PDU
Replacing a PDU—Part Number CTS-PWR-PDU
There are two PDUs attached to the left accessory cabinet, one attached to the right accessory cabinet,
one PDU attached to the underside of the tabletop, and one attached to the center display st ructure.
Step 1 On the PDU to be replaced, turn the power switch to Off and remove the plug from the wall receptacle.
Step 2 Remove any cables plugged into the PDU.
Step 3 Remove the PDU from the accessory cabinet or center Privacy panel by removing the mounting screws.
Step 4 Attach the replacement PDU.
Step 5 Plug in the jumper cords that were removed and turn the power switch to the On position.
Step 6 Plug the PDU power cord into the wall receptacle.
Step 7 Open a browser on a computer connected to the network.
Step 8 Type in the IP address of the center, primary codec unit. Enter the required information at the login
screen. The Cisco TelePresence Administrator window appears.
Step 9 Verify the status of the Cisco Unified Communications Manager (seen in the lower left portion of the
window) is Enabled/Up.
Step 10 Choose System Restart to perform a software reset.
Refer to the Cisco TelePresence System Administrator's Guide for your software release for more
information.