Monitoring the Environment

RPS Output Voltage status: normal

RPS Fan status: normal

RPS Thermal status: normal

RPS OverVoltage status: normal

Environmental monitor experienced the following events:

Temperature:sensor failed.

Fans:monitor dropped.

Temperature:warning.

Temperature:sensor recovered.

Fans:monitor recovered.

Fans:normal.

The display below appears on your console when the system reaches a critical state:

Router# show environment

Temperature:

Temperature Reading:

Temperature at inlet is measured as 62C/143F.

Temperature at outlet is measured as 74C/165F.

Temperature State:

Temperature is in critical state.

DFC Busyout/Power-down:

A DFC is powered down. Slot:1, Type:NP108 DFC

A DFC is busyout. Slot:2, Type:T1 8 PRI DFC

A DFC is busyout. Slot:3, Type:NP108 DFC

Fans:

Fans temperature delta is measured as 6C.

All fans are running well.

Power Supply:

Redundant Power System is present.

RPS Input Voltage status: normal

RPS Output Voltage status: normal

RPS Fan status: normal

RPS Thermal status: normal

RPS OverVoltage status: normal

Environmental monitor experienced the following events:

Temperature:sensor failed.

Fans:monitor dropped.

Temperature:warning.

Temperature:sensor recovered.

Fans:monitor recovered.

Fans:normal.

Temperature:critical.

The display below appears on your console when the system reaches a shutdown state:

Router# show environment

Temperature:

Temperature Reading:

Temperature at inlet is measured as 70C/158F.

Temperature at outlet is measured as 82C/179F.

Temperature State:

Temperature is in shutdown state.

DFC Busyout/Power-down:

A DFC is powered down. Slot:1, Type:NP108 DFC

A DFC is powered down. Slot:2, Type:T1 8 PRI DFC

A DFC is powered down. Slot:3, Type:NP108 DFC

Fans:

Fans temperature delta is measured as 6C.

All fans are running well.

 

 

 

Power Supply:

 

 

 

Redundant Power System is present.

 

 

 

RPS Input Voltage status: normal

 

 

 

RPS Output Voltage status: normal

 

 

 