Appendix A CSG2 Command Reference

ip csg radius pod attribute

The CSG2 saves only those attributes or subattributes which meet both of the following criteria:

They are present in the new RADIUS Accounting Start or RADIUS Interim Accounting Request.

They are configured for reporting at the time the new request arrives at the CSG2.

All previously stored attribute and subattribute information from previous requests is destroyed, even if the new RADIUS Accounting Start or RADIUS Interim Accounting Request does not contain all of the attributes and subattributes that were present in the previous request. Only the currently stored attributes are reported in CDRs.

If there are multiple instances of an attribute, all instances are included. Attributes are included in the PoD message in random order.

Examples

 

The following example shows how to specify RADIUS attributes 44 and 26:

 

 

ip csg radius pod attribute 44

 

 

ip csg radius pod attribute 26

 

 

 

 

Related Commands

 

Command

Description

 

 

 

 

 

 

ip csg radius pod nas

Specifies the NAS port to which the CSG2 is to send the PoD message,

 

 

 

and the key to use in calculating the Authenticator.

 

 

 

 

 

 

ip csg radius pod timeout

Specifies the number of times to retry the RADIUS PoD message if it

 

 

 

is not acknowledged by means of an ACK message, and the interval

 

 

 

between retransmissions.

 

 

 

 

 

 

Cisco Content Services Gateway - 2nd Generation Release 2.0 Installation and Configuration Guide

 

 

 

 

 

 

 

OL-15491-01

 

 

A-127

 

 

 

 

 

Page 127
Image 127