Appendix A CSG2 Command Reference

meter minimum

meter minimum

To specify the minimum number of quadrans debited by the CSG2 for a service or session, use the meter minimum command in CSG2 service configuration mode. To return to the default behavior, use the no form of the command.

meter minimum value no meter minimum value

Syntax Description

 

value

Minimum number of quadrans debited for a service or session,

 

 

 

excluding the value in meter initial. For example, to force the CSG2

 

 

 

to debit 90 quadrans when less than 90 quadrans of network usage

 

 

 

were used for the service, specify meter minimum 90. If the initial

 

 

 

value is 20 quadrans and the minimum is 90 quadrans, then the

 

 

 

minimum total charge is 110 quadrans. The minimum value is

 

 

 

applied only if at least 1 session is granted network access for the

 

 

 

service.

 

 

 

The range is from 0 to 65535. The default value is 0.

 

 

 

 

 

 

 

 

 

Defaults

 

The default number is 0 quadrans.

 

 

 

 

Command Modes

 

CSG2 service configuration

 

 

 

 

 

Command History

 

Release

Modification

 

 

 

 

 

 

12.4(11)MD

This command was migrated from CSG1.

 

 

 

Changes from CSG1: None.

 

 

 

 

 

 

If meter initial is set to 20 quadrans, and meter minimum is set to 90 quadrans, then the minimum total

Usage Guidelines

 

 

 

charge is 110 quadrans.

If service duration is configured in the basis command, the usage is rounded up to the minimum value when the Service Stop is sent. For a minimum value of 90, 150 seconds of network usage is not rounded up for the purpose of calculating usage in the Service Stop, but, for example, 63 seconds of network usage is rounded up to 90 quadrans.

Note The rounding-up of network usage is not reflected in calculations for the Usage

Tag-Length-Value (TLV) in Service Reauthorization Requests.

 

 

Cisco Content Services Gateway - 2nd Generation Release 2.0 Installation and Configuration Guide

 

 

 

 

 

 

 

OL-15491-01

 

 

A-195

 

 

 

 

 

Page 195
Image 195