Cisco Systems PRP-2/R= Parameter RJ-45, Lists Ieee 802.3u physical characteristics for 100BASE-TX

Models: PRP-1/R= PRP-1= PRP-2/R= PRP-2=

1 92
Download 92 pages 52.96 Kb
Page 47
Image 47

Configuring Interfaces on the PRP

Table 4 lists the cabling specifications for 100-Mbps transmission over unshielded twisted-pair (UTP) cables.

Note The transmission speed of the Ethernet ports is auto-sensing by default and is user configurable.

Table 4

Specifications and Connection Limits for 100-Mbps Transmission

 

 

 

Parameter

 

RJ-45

 

 

Cable specification

Category 51 UTP, 22 to 24 AWG2

Cable length (max)

 

 

Segment length (max)

328 feet (100 m) for 100BASE-TX

 

 

Network length (max)

656 feet (200 m)3 (with one repeater)

1.EIA/TIA-568 or EIA-TIA-568 TSB-36 compliant. Not supplied by Cisco.

2.AWG = American Wire Gauge. This gauge is specified by the EIA/TIA-568 standard.

3.This length is specifically between any two stations on a repeated segment.

Table 5 lists IEEE 802.3u physical characteristics for 100BASE-TX.

Table 5

IEEE 802.3u Physical Characteristics

 

 

 

Parameter

 

100BASE-TX

 

 

Data rate (Mbps)

100

 

 

Signaling method

Baseband

 

 

Maximum segment length

100 m between DTE1 and repeaters

Media

 

Category 5 UTP (for RJ-45)

 

 

 

Topology

 

Star/Hub

 

 

 

1. DTE = data terminal equipment.

 

 

Performance Route Processor Installation and Configuration Guide

 

 

 

 

 

 

OL-11656-01

 

 

47

 

 

 

Page 47
Image 47
Cisco Systems PRP-2/R=, PRP-1=, PRP-1/R=, PRP-2= Parameter RJ-45, Lists Ieee 802.3u physical characteristics for 100BASE-TX