Configuring PoE

Configuring Power Policing

 

Command or Action

Purpose

 

 

power inline police action logGenerates a syslog message

 

 

while still providing power to the port.

 

 

If you do not enter the action log keywords, the default action shuts

 

 

down the port and puts the port in the error-disabled state.

Step 4

exit

Returns to global configuration mode.

Example:

Switch(config-if)# exit

Step 5 Use one of the following:

errdisable detect cause inline-power

errdisable recovery cause inline-power

errdisable recovery interval interval

Example:

Switch(config)# errdisable detect cause inline-power

Switch(config)# errdisable recovery cause inline-power

Switch(config)# errdisable recovery interval 100

(Optional) Enables error recovery from the PoE error-disabled state, and configures the PoE recover mechanism variables.

By default, the recovery interval is 300 seconds.

For interval interval, specifies the time in seconds to recover from the error-disabled state. The range is 30 to 86400.

Step 6

exit

Returns to privileged EXEC mode.

 

Example:

 

 

Switch(config)# exit

 

Step 7

Use one of the following:

Displays the power monitoring status, and verify the error recovery

 

 

settings.

show power inline police

show errdisable recovery

Example:

Switch# show power inline police

Switch# show errdisable recovery